Basic electrical theory explains how voltage, current, resistance and power relate in a circuit. Voltage is the pressure that pushes charge, current is the flow of that charge, resistance opposes the flow, and power is the rate at which energy is used. Ohm's law (E = I × R) and the power formula (P = E × I) connect all four, and in AC circuits, reactance and impedance extend the same ideas.

This guide builds that foundation in the order you need it for the journeyman exam: the four quantities, Ohm's law and power, conductors and wire resistance, series and parallel circuits, AC vs DC, reactance and impedance, power factor, three-phase systems and transformers. Each section links to a deeper guide, and every example is worked out step by step so you can check your own math.

The four quantities: voltage, current, resistance and power

Every electrical calculation uses some combination of these four. Learn the letter, unit and meaning of each, because exam questions switch between them constantly.

QuantitySymbolUnitWhat it is
Voltage (electromotive force)E (or V)volt (V)The electrical pressure that pushes charge
CurrentIampere (A)The rate of flow of charge
ResistanceRohm (Ω)Opposition to current flow
PowerPwatt (W)The rate at which energy is converted

Voltage is a difference in electrical potential between two points. A 120-volt receptacle has 120 volts between the ungrounded conductor and the grounded (neutral) conductor. Voltage can exist without current, like a receptacle with nothing plugged in.

Current is the flow of charge through a complete path. One ampere is one coulomb of charge per second. Current only flows when there is a closed loop from the source, through the load and back.

Resistance converts electrical energy into heat. Heater elements and incandescent filaments are designed for it; conductors are designed to minimize it.

Power is how fast energy is being used. A 1,500-watt heater uses energy three times as fast as a 500-watt one. Energy is power over time, billed in kilowatt-hours: 1,500 W running for 4 hours uses 1.5 kW × 4 h = 6 kWh.

These units come from the International System of Units (SI). The NIST SI units reference lists the ampere as one of the seven base units; the volt, ohm and watt are derived from it and the other base units.

Switch120 Vsource10 ΩLoad1,440 WI = E ÷ R = 120 ÷ 10 = 12 AP = E × I = 120 × 12 = 1,440 W
A complete circuit: the source provides voltage, current flows through the closed path, and the load's resistance converts energy to heat or work.

Ohm's law: the relationship behind every calculation

Ohm's law states that current is directly proportional to voltage and inversely proportional to resistance:

Ohm's law

E = I × R · I = E ÷ R · R = E ÷ I

Double the voltage across a fixed resistance and the current doubles. Double the resistance at a fixed voltage and the current is cut in half.

The power formula adds watts:

Power

P = E × I · P = I² × R · P = E² ÷ R

Combine them and you get twelve formulas, usually drawn as the "power wheel." You do not need to memorize all twelve if you can rearrange E = I × R and P = E × I. Our guide to Ohm's law and the power formula wheel walks through every variation with exam-style twists, and the electrical formulas cheat sheet puts them on one page with the single-phase, three-phase, voltage drop and transformer formulas.

Worked example

Space heater on a 120-volt circuit

  1. 1

    The question

    A 1,500-watt, 120-volt space heater is plugged in. What current does it draw, and what is the resistance of its element?

  2. 2

    Current

    I = P ÷ E = 1,500 ÷ 120 = 12.5 A.

  3. 3

    Resistance

    R = E ÷ I = 120 ÷ 12.5 = 9.6 Ω. Check with R = E² ÷ P = 14,400 ÷ 1,500 = 9.6 Ω.

  4. ✓ Answer: 12.5 amperes and 9.6 ohms. On a 15-ampere circuit, that one heater uses most of the circuit's capacity.

Conductors, insulators and wire resistance

Conductors have many free electrons and let current flow easily: copper and aluminum are the conductors of building wiring. Insulators (such as the PVC and nylon on THHN) resist current flow and keep it where it belongs.

Even good conductors have resistance, and it depends on four things:

  1. Material. Aluminum has more resistance than copper of the same size, which is why aluminum conductors must be larger for the same ampacity.
  2. Length. Resistance increases in direct proportion to length. Twice as long, twice the resistance.
  3. Cross-sectional area. Larger conductors have less resistance. In AWG sizes, a smaller number means a larger wire.
  4. Temperature. The resistance of copper and aluminum increases as they get hotter.

The NEC lists conductor resistance in Chapter 9, Table 8 (DC resistance at 75°C) and Table 9 (AC resistance and reactance). For example, Table 8 lists 1.98 Ω per 1,000 feet for 12 AWG uncoated stranded copper.

Worked example

Resistance and heat in a branch circuit

  1. 1

    The question

    A 120-volt circuit uses 12 AWG stranded copper. The load is 100 feet from the panel and draws 16 amperes. What is the conductor resistance, the voltage drop and the heat lost in the wire?

  2. 2

    Total conductor length

    Current flows out and back: 2 × 100 ft = 200 ft.

  3. 3

    Resistance

    R = 200 ÷ 1,000 × 1.98 Ω = 0.396 Ω.

  4. 4

    Voltage drop and heat

    VD = I × R = 16 × 0.396 = 6.34 V (about 5.3% of 120 V). Heat in the wire: P = I² × R = 256 × 0.396 = 101 W.

  5. ✓ Answer: About 0.40 Ω, 6.34 volts dropped and 101 watts of heat in the conductors. That is why long runs are often upsized.

This is the core idea behind voltage drop calculations and behind ampacity limits in the wire ampacity chart (Table 310.16): current through resistance makes heat, and insulation can only take so much heat.

Series and parallel circuits

Loads can be connected in series (one path, same current through every load) or in parallel (separate branches, same voltage across every branch). Most building wiring is parallel: every receptacle and light on a circuit sees the full circuit voltage.

SeriesParallel
CurrentSame through every loadDivides among branches; total = sum of branches
VoltageDivides among loads; total = sum of dropsSame across every branch
Total resistanceR₁ + R₂ + R₃… (larger than any one)1 ÷ (1/R₁ + 1/R₂ + …) (smaller than the smallest)
One load opensEverything stopsOther branches keep working

Quick check: three 30-ohm resistors in series total 90 Ω; in parallel they total 30 ÷ 3 = 10 Ω. The full rules, combination circuits and exam traps are in series vs parallel circuits.

AC vs DC

Direct current (DC) flows in one direction at a constant value: batteries, solar modules and most electronics inside their power supplies. Alternating current (AC) reverses direction continuously, following a sine wave. Utility power in the United States alternates at 60 hertz (60 complete cycles per second), so each cycle lasts 1 ÷ 60 = 0.0167 seconds, about 16.7 milliseconds.

Buildings use AC mainly because transformers can raise and lower AC voltage efficiently. Utilities transmit power at high voltage (low current, low losses) and step it down near the customer.

RMS, peak and average values

An AC voltage is constantly changing, so we need one number to describe it. That number is the RMS (root mean square) or effective value: the DC voltage that would produce the same heat in a resistor. When the NEC or a nameplate says 120 V, that is RMS.

For a pure sine wave:

Sine wave relationships

Peak = RMS × 1.414 · RMS = Peak × 0.707

So a 120-volt circuit actually peaks at 120 × 1.414 = 169.7 V, and swings from +169.7 to −169.7 V, a peak-to-peak value of about 339 V. Insulation ratings and surge protection have to account for those peaks.

Peak +169.7 VRMS 120 V1 cycle = 1/60 sPeak −169.7 V
One cycle of 120-volt, 60 Hz AC. The meter reads the RMS value (120 V); the wave actually peaks near 170 V.

Nominal voltage

Real voltage at a receptacle varies with load and utility conditions, so the NEC uses nominal values for calculations. NEC 220.5(A) lists the nominal voltages to use unless other voltages are specified: 120, 120/240, 208Y/120, 240, 347, 480Y/277, 480, 600Y/347 and 600 volts. That is why exam answers use 120 and 240, not 110 and 220. See 110 vs 120 volts and nominal voltage for the full explanation.

How voltage levels are classified (low, medium and high) depends on whether you are reading the NEC, OSHA or an industry standard; what is considered high voltage sorts out the definitions.

Inductance, capacitance, reactance and impedance

In AC circuits, two more components oppose current flow without turning energy into heat the way a resistor does.

Inductance (L, henrys) comes from coils: motor windings, transformer windings and ballasts. An inductor opposes changes in current and causes current to lag voltage. Its opposition, inductive reactance, grows with frequency:

Inductive reactance

X_L = 2 × π × f × L

Capacitance (C, farads) comes from two conductors separated by insulation, such as a motor-run capacitor or a long cable. A capacitor causes current to lead voltage. Its opposition, capacitive reactance, falls as frequency rises:

Capacitive reactance

X_C = 1 ÷ (2 × π × f × C)

Worked values at 60 Hz:

  • A 0.1-henry coil: X_L = 2 × 3.1416 × 60 × 0.1 = 37.7 Ω.
  • A 100-microfarad capacitor (0.0001 F): X_C = 1 ÷ (2 × 3.1416 × 60 × 0.0001) = 1 ÷ 0.0377 = 26.5 Ω.

A memory trick many electricians use is ELI the ICE man: in an inductive (L) circuit, voltage E comes before current I (ELI); in a capacitive (C) circuit, current I comes before voltage E (ICE).

Impedance: total opposition in AC circuits

Impedance (Z), measured in ohms, is the total opposition to AC current. Because reactance is 90 degrees out of step with resistance, you cannot simply add them. They combine like the sides of a right triangle:

Impedance (series R and X)

Z = √(R² + X²) · where X = X_L − X_C

Ohm's law still works with impedance: I = E ÷ Z.

R = 30 ΩXL = 40 ΩZ = 50 ΩθZ = √(30² + 40²)= √2,500 = 50 ΩAt 120 V:I = 120 ÷ 50 = 2.4 APF = 30 ÷ 50 = 0.6
The impedance triangle for R = 30 Ω and X_L = 40 Ω. The hypotenuse is Z = 50 Ω, and power factor = R ÷ Z = 0.6.

Power factor, kW and kVA

In a circuit with reactance, voltage and current are out of step, so E × I overstates the real work being done. That gives three kinds of power:

  • True power (watts, W or kW): the power that does work or makes heat.
  • Apparent power (volt-amperes, VA or kVA): E × I, what the conductors and transformers must carry.
  • Reactive power (VAR or kVAR): power that sloshes back and forth to build magnetic and electric fields.

Power factor is the ratio of true power to apparent power, and in a series R-X circuit it also equals R ÷ Z:

Power factor

PF = W ÷ VA = R ÷ Z

Worked example

An inductive load at 120 volts

  1. 1

    The question

    A load has 30 Ω of resistance and 40 Ω of inductive reactance on a 120-volt circuit. Find the current, apparent power, power factor and true power.

  2. 2

    Impedance and current

    Z = √(30² + 40²) = √(900 + 1,600) = √2,500 = 50 Ω. I = 120 ÷ 50 = 2.4 A.

  3. 3

    Apparent power and power factor

    VA = 120 × 2.4 = 288 VA. PF = 30 ÷ 50 = 0.6.

  4. 4

    True power, checked two ways

    W = VA × PF = 288 × 0.6 = 172.8 W. Check: I² × R = 2.4² × 30 = 5.76 × 30 = 172.8 W.

  5. ✓ Answer: 2.4 A, 288 VA, PF 0.6 and 172.8 W. Conductors must carry the full 2.4 A even though only 172.8 W does useful work.

Power factor is why motor and transformer calculations use VA and kVA, not just watts. The full treatment, including how power factor changes the current you size for, is in power factor, kW and kVA.

Single-phase and three-phase power

A single-phase system has one alternating voltage. Homes in the US are typically served at 120/240 V single-phase: two ungrounded conductors with 240 V between them, and 120 V from each to the grounded neutral.

A three-phase system has three voltages, each 120 degrees apart. It delivers power more smoothly, lets motors start and run without extra starting components, and carries more power per conductor. Line-to-line and line-to-neutral voltages in a wye system are related by the square root of 3:

Wye voltages

E_line = E_phase × 1.732 · 120 V × 1.732 = 208 V

Three-phase power and current use the same factor:

Three-phase power

P = E × I × 1.732 × PF

For the full comparison and calculations, read single-phase vs three-phase power. Three-phase transformers are connected in delta or wye, which changes the voltages you get; see delta vs wye. One delta configuration produces a phase with about 208 V to ground that must be marked and placed correctly: the high-leg delta (wild leg).

Transformers: changing voltage and current

A transformer has two windings on a shared iron core. AC in the primary creates a changing magnetic field that induces voltage in the secondary. The voltage ratio equals the turns ratio:

Transformer ratio (ideal)

E_p ÷ E_s = N_p ÷ N_s = I_s ÷ I_p

Voltage and current trade off: step the voltage down by half and the available current doubles. The VA stays the same on both sides (ignoring small losses).

Example: a single-phase transformer with a 2:1 ratio takes 480 V in and delivers 240 V out. If the primary carries 10 A, the primary is 480 × 10 = 4,800 VA, so the secondary can deliver 4,800 ÷ 240 = 20 A. Transformers only work on AC; a steady DC current produces no changing field and induces nothing in the secondary.

Sizing transformers and their overcurrent protection is a code topic in its own right; see transformer calculations.

Exam-style questions on electrical theory

Exam-style question

A resistive load draws 8 amperes from a 240-volt circuit. What is the resistance of the load?

Pick an answer to see the explanation.

Exam-style question

What is the peak voltage of a 240-volt RMS sine wave?

Pick an answer to see the explanation.

Exam-style question

A series AC circuit has 6 Ω of resistance and 8 Ω of inductive reactance. What is its impedance?

Pick an answer to see the explanation.

Exam-style question

In a purely inductive AC circuit, how does current relate to voltage?

Pick an answer to see the explanation.

How theory is tested on the journeyman exam

The share of theory questions varies by state and testing provider, so check your candidate bulletin. Across most journeyman exams, theory shows up in three ways:

  1. Direct formula questions: find current, resistance, power or impedance.
  2. Applied calculations: voltage drop, three-phase current, transformer full-load current, motor current.
  3. Concept questions: what happens to current when resistance doubles, which value a meter reads, what leads and what lags.

The calculations get harder, but they never leave the foundation. If you can do Ohm's law, the power formula and the 1.732 factor cleanly, you can handle most of the math on the exam. The math errors that cost the most points are simple ones: using E × I when the question asks for resistance, forgetting the 2 in "out and back" conductor length, adding resistance and reactance directly, and mixing up line and phase values.

Where to go next

Work through the electrical theory guides in this order: Ohm's law, series vs parallel circuits, power factor and kVA, single-phase vs three-phase, delta vs wye and the high-leg delta. Keep the electrical formulas cheat sheet open while you study, and check nominal voltage and voltage classes when a question hinges on which voltage to use.

To see how these topics fit with the code questions, read what is on the journeyman electrician exam, then put your theory under the clock with a free journeyman electrician practice test.